Nebulizer Machine

Description: TEDAMED is the leading manufacturer of nebulizer machine in China

Flow

6.7L / min

Working pressure range

9.5-19psi

Compressor pressure range

22-58psi

Sound level

65dB (A)

Operating humidity range

15 to 80% RH

Certification

CE,ISO

Nebulizer Machine

Tedamed nebulizer  is one of the most successful solutions to treat chest infections in children and the elderly, such as asthma, popular suits and bronchitis, because tedamed nebulizer depends on the direct injection of effective drugs to the lungs, so that the effect is faster than that for the child, where he needs to run with blood flow, and then the body extracts effective drug ingredients and gets the place it needs.

Features:

Low noise
Latex free
Easy to clean
Two storage compartments
Comes with a complete nebulizer kit

INTRODUCTION

Thank you for purchasing the Compressor Nebulizer. It is a compact medical device designed to efficiently deliver physician-prescribed medication to the bronchial lung passages. With proper care and use, it will provide you with many years of reliable treatment.
This product is developed for the successful treatment of asthma, allergies, and other respiratory disorders. It creates a stream of air that travels through a clear tube to the nebulizer.When air enters the nebulizer,it will convert the prescribed medication into aerosol mist for easy inhalation.
Your Compressor Nebulizershould be used under the supervision ofalicensed physician and/or a respiratory therapist.We encourage you to thoroughly read this guidebook to learn about the features of this product. Any use of this product other than its intended use should always be avoided.

IMPORTANT SAFEGUARDS

Note:Read all instructions carefully before use.
The following basic precautions are needed when using an electrical product:
Caution:Failure to read and observe all precautions could result in personal injury orequipmentdamage

Productcautions:
1. To avoid electrical shock: Keep the unit away from water Do not immerse the
power cord or the unit in liquid Do not use while bathing Do not reach for a unit that has fallen into water immediatelyunplug the unit.
2. Never operate the unit ifit has any damagedparts(including power cord),ifit
has been dropped or submersed in water. Promptly send it to a service center for examination and repair.
3.The unit should not be used where flammable gas, oxygen or aerosol spray
products are being used.
4. Keep the air vents open. Do not place the unit on a soft surface where the
openings can be blocked.
5.lfthe medicine cupis empty,do notattemptto operatethe unit
6.lfanyadnormalityoccurs,discontinue use until the unit has been examined and
repaired.
7.The unit should not be left unattended while plugged in.
8. Do not tilt or shake the unit when in operation.
9. Disconnect the unit from the electrical outlet before cleaning, filling and afte
each use.
10.Do not use other attachments unless recommended by manufacturer.

Operating Cautions:

Connect this product to an appropriate voltage outlet for your model. Do not run this product unattended.
Never operate if this unit has a damaged cord or plug, if it has been dropped,or in any way, submerged into water, if it does not work properly. Return it to a service center for repair.
Ifany abnormality occurs, discontinue use immediately until the unit has been examined and repaired.
Always unplug the product immediately after use.
Never block the air openings of the main unit or place it where the air openings maybe obstructed.

Storage Cautions:

Do not store the unit under direct sunlight, high temperature or humidity. Keepthe unit outofreach ofsmall children
Always keep the unit unplugged while not in use.

Cleaning Cautions:

Do not immerse the unit in water.It may damage the unit.
Disconnect the unit from the electrical outlet before cleaning.
Clean all necessary parts after each use as instructed in this guidebook.

OPERATING YOUR COMPRESSOR NEBULIZER

Note:Prior to initial operation,the nebulizer should be thoroughly cleaned.
Place your Compressor Nebulizer on a flat and stable surface.Be sure thatyou can easily reach the controls when you are seated
Gently twist the top part of the nebulizer counter-clockwise to disassemble the nebulizer.
Fill the bottom section of the nebulizer with the medication prescribed by your physician.Be sure that the cone is put inside the bottom section. Gently twist the top part clockwise to reassemble the nebulizer Be sure the two sections fit well.
Attach one end of air tube to the base of the nebulizer.
Attach the other end of air tube to the tube connector located on the front of the compressor.
Attach mouthpiece or mask per your choice to the top section of nebulizer.
Plug the power cord into an appropriate electrical outlet. Make sure at this stage,the power switch is at “Off” status Press power switch to begin your prescribed treatment.

Important:

The compressor motor has a thermal protector, which will shut off the unit before the unit is overheated.When the thermal protector shuts the unit off,please:
+Switch off the unit.
+ Unplug the unit from the electrical outlet.
+ Wait 30 minutes for the motor to cool down before another treatment. Make sure the air openings are not obstructed
When treatment is finished,shut off the unit and unplug it from the electrical outlet.

CLEANING

It is recommended that the nebulizer, mouthpiece and mask be thoroughly cleaned with hot water after each use and cleaned with a mild detergent after thelast treatment of the day. lf your physician or respiratory therapist specifies a different cleaning procedure,follow their instructions.

Rinsing(after each treatment):

Disconnect the air tube,nebulizer,mouthpiece and mask. Gently twist the nebulizer to open it.
Rinse the nebulizer,mouthpiece and mask with water. Dry them with clean soft towel or let it air dry.
Reassemble the nebulizer when completely dry and put these parts in a dry, sealed container.

Disinfections:

Please follow the following steps to disinfectyour nebulizer unless otherwise specified by your physician. lt is suggested that the unit is disinfected after the last treatment of the day.
Use one part white vinegar with three parts distilled water.Make sure mixed Ssolution is enough to submerge the nebulizer,mouthpiece,and mask. Complete Rinsing Steps 1-3.
Wash nebulizer,mouthpiece and mask in warm water and a mild detergent.Then wash them in hot tap water.
Submerge these parts in the vinegar and water solution for thirty minutes. CompleteRinsingSteps3-5

Cleaning the compressor:

Wipe dailywith a damp cloth.Do not use any powdered cleaners or soap pads,which may damage the finish. 

Filter change:
Do not use cotton or any other materials. Do not wash or clean the filter. Only use filters supplied by your distributor. And do not operate without a filter. Change the filter every 30 days or when the filter turns gray. Changing procedure:
+Remove the filter cover.
+Replace the used filter with a new one.+Replace the filter cover.

REPLACEMENT PARTS & OPTIONALACCESSORIES

Replacement pars are ailial through your local retailer or they can be Ordered by email: optional accessories child mask. nose piece and baby pacifier inhaler. easily through normal breath.

SPECIFICATIONS

  1. Voltage: AC 220V/50Hz
  2. Power :168VA
  3. Medication Capacity:8 ml
  4. Particle Size :0.5-10um
  5. Sound Level :≤65 dB(A)(1 meter away)
  6. Average Neuiaion Rate :≥20.25mL/min (0.9% saline water)
  7. Compressor Pressure Range :22.- 58psi(150-400kPa)
  8. Operating Pressure Range :9.5 -19psi (65-130kPa)
  9. Liter Flow Range: 26.7L/Min
  10. Operating Temperature Range: 5*C~40*C(41F~ 104*F)
  11. Operating Humidity Range :15~80%RH
  12. Storage Temperature Range: -25*C~60*C(-13°Fto140*F)
  13. Dimension: 300x180x110mm
  14. Weight: 1.5kg
  15. Standard Accessories :Wvbuizer Ar Tue dutisk, hi’s Mask Mouthpiece, Filters (5)_
  16. Use life: 5 years

Protection against electric shock: – Class Ⅱ equipment

contact us

Request a Quick Quote

We will contact you within one business day, please pay attention to the email with the suffix “tedamed”.